2021久久精品永久免费,国产又粗又大又黄,亚洲精品国产美女久久久99,人妻中出中文字幕一区二区,国产免费一级在线观看,99re视频在线,伊人色综合久久天天人手人婷,亚洲精品国产男人的天堂,在线天堂中文一区二区三区,宝贝腿开大点我添添公口述视频

產品分類

Products

技術文章/ ARTICLE

我的位置:首頁  >  技術文章  >  ASJ系列剩余電流動作繼電器

ASJ系列剩余電流動作繼電器

更新時間:2022-11-21      瀏覽次數:1024

安科瑞 陳聰

ASJ series Residual Current Action Relay

1. 概述

Overview

在工業(yè)應用中,剩余電流繼電器與外部剩余電流互感器結合使用以檢測和評估接地故障電流。它們也可以與保護裝置結合使用,以實現(xiàn)電路的斷開,從而實現(xiàn)對線路和人員的保護。

Residual current relay can be combined with external residual current transformer to detect and evaluate the ground fault current. They can also be combined with protective devices to realize the disconnection of circuits and the protection of lines and workers.

2.剩余電流的定義以及危害

Definition and risk of residual current

剩余電流,是指低壓配電線路中各相(含中性線)電流矢量和不為零的電流。通俗講當用電側發(fā)生了事故,電流從帶電體通過人體流到大地,使主電路進出線中的電流I相和I中的大小不相等,此時電流的瞬時矢量合成有效值稱為剩余電流,俗稱漏電。

Residual current is the current vector sum of each phase (including the neutral ) in the low-voltage distribution that not be zero. Generally, when there is an accident on the power side, the current flows from the charged body to the earth through the human body,it will cause that the current phase I in the main circuit not equal to the size in phase I. At this time, the value of instantaneous current vector synthesis is called residual current, commonly known as leakage.

TN System

 

1.png


3.剩余電流的危害:

Risk of residual current:

人身觸電。當電氣設備因絕緣損壞而使外殼帶電,而工作人員又接觸此外殼時,就會導致人身觸電事故。

(1)Physical electric shock. When shell of the electrical equipment is electrified due to insulation damage, and the workers touch the shell again, it will lead to physical electric shock accident.

燒損電氣設備,引起火災。長期存在的漏電電流,尤其是兩相經過電阻接地的漏電電流,在通過設備絕緣損壞處時將散發(fā)出大量的熱,使絕緣進一步損壞,甚至使可燃性材料(如非阻燃性橡套電纜)著火燃燒。

Burn electrical equipment and cause fire. The long-term leakage current, especially the leakage current of  two-phase grounded through resistance, will release a lot of heat when flow through the damaged part of the equipment insulation, further damaging the insulation, and even making combustible materials (such as non flame retardant rubber sheathed cable) burn on fire.

引起短路事故。據統(tǒng)計,約有30%的單相接地故障發(fā)展為短路。從而造成更大的電氣故障。長期存在的漏電電流及電火花使漏電處的絕緣進一步損壞,后危及相間絕緣而造成短路。

(3) Cause short circuit accident. According to statistics, about 30% of single-phase grounded faults develop into short circuit which will give rise to heavier electrical failure. The long-term leakage current and spark further damage the insulation at the leakage point, and finally endanger the interphase insulation and cause short circuit.

引起電氣火災事故。電網發(fā)生單相接地或設備發(fā)生單相碰殼時,在接地點就會產生電火花,若此電火花具有足夠的能量,就可能點燃易燃易爆物品。

Cause electrical fire accident. When the single-phase grounding occurs in the power grid or the single-phase collision occurs in the equipment, the electric spark will be generated at the grounding point. If the electric spark has enough energy, it may ignite flammable and explosive materials.

4.如何測剩余電流

How to measure residual current

在被測的三相導線路上與N線上各裝一個CT,或讓三相導線與N線一起穿過一個零序CT,得到三相導線與中性線N的電流矢量和IA*+IB*+IC*+IN*,當沒有發(fā)生單相接地故障時,無論三相負荷平衡與否,則此矢量和為零;當發(fā)生某一相接地故障時,故障電流中會通過保護PE及與地相關連的金屬構件回到電源,即IA*+IB*+IC*+IN*,此時數值為接地故障電流Id。

Installing a CT on each of the three-phase conducting lines to be tested and N line or let the three-phase conductor and the n-line pass through a zero sequence CT together to get the current vector sum IA * + IB * + IC * + IN * . when there is no single-phase grounded fault, whether the three-phase load is balanced or not, the vector sum is zero; when there is a phase grounded fault, the fault current will flow through the protection PE and the metal components connected to the earth to the power supply, at this time, the value is the ground fault current Id.


5.ASJ系列剩余電流動作繼電器

ASJ series residual current operated relay

ASJ系列剩余電流動作繼電器可與低壓斷路器或低壓接觸器等組成組合式剩余電流保護裝置, 主要適用于交流 50Hz, 額定電壓 400V 及以下的 TT 和 TN 系統(tǒng)配電線路, 用來對電氣線路進行接地故障保護, 防止接地故障電流引起的設備損壞和電氣火災事故, 也可用來對人身觸電危險提供間接接觸保護。

ASJ series residual current action relay can be combined with low voltage circuit breaker or low voltage contactor to form a combined residual current protection device.It is mainly used for TT and TN system distribution lines with AC 50Hz and rated voltage of 400V and below.It is used to protect the electrical circuit from ground faults, prevent equipment damage caused by ground fault current and electrical fire accidents, and can also be used to provide indirect contact protection against personal electric shock hazard

4.png

5.png

6.png

7.png


參考文獻 Bibliography

1.Solutions For Enterprise Micro-grid System 2020.02


蘇公網安備 32028102001251號

特黄特色的大片观看免费视频| 色呦呦 国产精品| 亚洲精品不卡无码福利在线观看| 亚洲色一区二区三区四区| 老司机亚洲精品影院| 国产太嫩了在线观看| 国产精品_国产精品_k频道 | 开心激情站一区二区三区| 校园春色 qvod| 扒开粉嫩的小缝隙喷白浆视频| 久久无码高潮喷水| 亚洲精品尤物av在线观看不卡| 免费国产裸体美女视频全黄| 国产熟妇另类久久久久久| 亚洲 欧美 日韩 国产综合 在线| 久久精品一偷一偷国产| 91国在线啪精品一区| 亚洲综合久久久中文字幕| 中文字幕巨乱亚洲| 啦啦啦 中国 日本 免费观看| 亚洲成aⅴ人片精品久久久久久| 亚洲精品中文字幕二区| 亚洲国产精品综合久久20| 国产精品视频免费网站| 国产亚欧女人天堂AV在线 | 亚洲国产精品嫩草影院久久| 成人精品免费视频| 无码av最新无码av专区| 少妇扒开双腿让我看个够| 欧美日韩第一区| 亚洲精品无码成人aaa片| 中文字幕无码免费久久9一区9 | a级毛片无码免费真人久久| 国产精品久久久久这里只有精品| av无码av在线a∨天堂app| 国产又色又爽又黄的视频在线| 大地资源高清播放在线观看| 豆国产96在线 | 亚洲| 国产亚洲精品性爱视频| 手机福利视频| 国产福利姬喷水福利在线观看|